We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Hi I have a Hayward aquatrol above ground pool chlorine generator system. Also use a rag to clean the surfaces that mate on the pump body. What would have caused this? Does a Hayward super pump wired on 230v have to have a controller?.. For the leaking underneath, that sounds like the shaft seal SPX1600Z2 or it could be leaking around the plumbing fitting threads, where water exits the pump, and is running down the side of the pump and dripping off the bottom. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Hi Steven, probably the breaker tripped or the GFCI test button popped out due to some water touching some wire. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Automatic restart 2 minutes after error is corrected. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. Or to a light switch and then to a breaker, that would be more of a standard installation. 7. When I turn the switch on for the pool, the breaker flips immediately. Replace with exact duplicated MFD numbers. My prior one was over 12 years old so Im feeling uncertain. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. If plumbed backwards into the PUMP and RETURN ports, it would exhibit these symptoms. Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. Motor again started humming and had to repeat the above steps each time I moved to backwash. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Your salt level is between 2500-2600 parts per million (ppm). For over 2 months, lots of troubleshooting, actually RE-PIPED THE SECTION FROM POOL TO PUMP done by professionalpump still will not primedraws water, wont primeplayed with outflow and values, no primetook apart (my nemesis) Hayward Perflex DE filter, cleaned fingers, silicone on gaskets, put back (I have done this crappy job a hundred times so I am familiar with the process)no primefeel like draining the damn pool and junking the whole thing >:(. We have a Hayward ultra pro lx series pump for our above ground pool. I have a Hayward C900 Filter. It does this everyday and then starts working like normaly for the rest of the day. Hi Cortney, you can buy the cord separately, Hayward pump cord the cause is likely from something arcing within the plug outlet. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. A warranty process with Hayward may take awhile, a few weeks this time of year I would think. We have all these parts here: https://www.intheswim.com/c/valve-parts, I Installed a new Hayward VCSB216V solar pump. Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. Getting air in basket, changed gasket with lube still have the same issue. That is usually suitable, but 20 amp could also be used. Ive waited a few hours and tried again but no luck. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. Pump lid not on tight enough Usually it takes about 15 mins, and the switch will reset and the motor will start again on its own. So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. I reached into the impeller and grabbed it but it seemed still tight. My heater is not turning on, I dont see an error message but the light next to the fire icon is not on but the light in the yellow triangle is on, any idea on what that means? Also check all the wires, from the back of the terminal board, to the stat. Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. I think it only screws on in one direction, but unscrew it to check When in Filter Position, water should route in only one direction. If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. Question my Aquaririte is 3 years old. Hi Davy~ Reconnect the pipes and test it out! The usual spot is the pipe that threads into the pump did you use Teflon tape and/or silicone sealant on the threads? I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. When I try to start it the motor sounds like it tries to turn but doesnt and I get a pump stalled error. One washer on each side of the spring, you are correct. Was running fine. This is more of an indicator light than anything else. We have a Hayward Super Pump 260710 that is 1 hp.The pool was working fine when we opened it 1 week ago except after it would run for 15-20 mins the motor would trip the circuit breaker so we had an electrician replace the motor and check the electrical and that was fine; however, we cant get the pump primed. Hello, Im having an issue where my variable speed pump is pushing de back into the pool however it only does this when its running at a lower RPM and does not exhibit this issue when running at priming speed or a higher RPM. I could take a leap of faith by trying your suggestion of replacing the shaft seal first. "height": "219",
The LED light should go out. Vibration can also cause a similar noise. Gasket Maker. Please let me know what can be done if anything we may be calling for info. Hi, I just had an electrician install a Hayward Super II Energy Efficient Pump 3/4 HP SP3007EECA. Could that be the voltage then or is there another possibility? Good luck! Spray some ant killer around, and replace the capacitor, but first, check all connections, maybe check incoming power (to the motor) if you have a test meter. I get home from work and the pump is running. And you cant rule out a problem with the circuit board either. Any ideas why this would happen? Checked to see that there was no short in the wire with an ohms meter . A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. Replace with exact MFD number, printed on side. Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. Could have been an outlet problem too, make sure wires or terminals arent touching anything except each other. All breakers have some wiggle to them usually, but a very loose breaker could be a hazard for arcing or even fire so should be checked out, if so. Hi Mark, hard to say if it does not display any error code, the caution symbol on a Hayward Heater is usually accompanied by an error code, LO being the most common, for low water flow. Strange things that when I have a storm it doesnt break but I does a day after when day is perfect. In cases such as this, it is often wise to get things going sooner, and replace the pump (or motor) now, and sort out the money later unless you are able to cover the pool with a winter cover, to block the sun, or load up the pool with lots and lots of chlorine and daily brushing/skimming both of which could sustain the water for up to 2 weeks, in most cases. Lets see what we can do Too much air usually just gets pushed through the filter and back to the pool, or the pump will lose prime if there really is too much air. Any ideas? Hi Doug, my first guess would be that the motor was set to accept 230V but was given 115V, or vice versa. Hi Carolyn, yes either the thermostat or other temp sensor, if present, would be responsible for that symptom. Hola Ral, Podra ser una de 4 cosas: encendedor, sensor de fuego, baja presin de gas o el tablero de control. You could also use a Hayward 24 sand filter, item E3324. Hello , This is an inactive thread. Look for insect infestation. Our unit comes on for about 15 secs. Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. 2 yrs is unusual for bearings to go. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. Did you figure this out. I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. Any idea how to correct this. Step 5: Measure your cells polarity to ensure they meet system parameters. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. Hi George, that is a strange one, because you dont backwash, yet pressure returns to normal, just by shutting pump off for a minute, then restarting? If your cell looks like 4A, continue to Step 4. Could also be that your vacuum hose has a big split in it if this only happens during vacuuming. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Or a loose breaker. Harwil type flow switches can become damaged over time and will need replacement at some point. Hi Tim, when the windings in a motor are shorted, the motor is pretty much dead, they arent rewound anymore, like in the old days. I believe we have the drawing in air issue at filter, I cannot locate to purchase the o ring seal and valve cover for this model. My guess is they would pronounce it DOA, but may find something interesting, or may find no problem at all, which would lead you to suspect the wiring, breaker, timer the source of power. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. The components of a Hayward pool heater are also similar to gas heaters made by other manufacturers. But lack of sand should not cause a leaking problem. Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. Hi Davy, I have a brand new Hayward motor/pump as shown above on your site. I have an older Haywood super pump 3/4 hp, i replaced it with a new 3/4 hp motor. Any part # you can recommend ? If I try to shut it off, nothing happens. Motor was replaced then gfci breaker replaced to Hayward recommended breaker (same breaker I had first time) still tripping on every 4-5 days , 10 days inconstant times but again 99% of the time overnight. I checked the breaker and plug connection and they were fine. The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. If it is not, re-align your flow switch. There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. It could have also overheated, when this happens, it will work again after cooling down. Hi, my pump has power and makes no noise. I tried -no way .then 3 very strong men all tried all of them had to put stress on the plumbing pipes to get the darn thing loosened at all ..what a NGHTMARE no we are not over tightening any suggestions? Have a brand new Hayward power flo LX. Its a good piece of troubleshooting. Also, make sure you plug in the cell all the way. Are you using enough DE powder? Is that a reason to replace impeller? I put the pump back together and it still leaks. Any ideas as to what could be the problem? Make sure pump motor is set to accept 110V (may be wired to accept 220V), and that all wires for the cord are tight, and connected correctly to terminals L1 and L2, I have a hayward super pump model c48k2n143b1 sp2607x10a and i am trying to wire on the 115v but i dont have a switch to change from 220 or 115 and no diagram on the pump i try yesterday to pump work but was not pulling the water like it is suppose to and after 3 min the pump what very hot .. so i think it is on 220v are you able to help me. Thank You, Thank You, Thank You! Theory and practice | Find, read and cite all the research you need on ResearchGate Chapter 1: The Evil Emperor's Son. It happens every time. Hi Chad, when a motor makes no noise at all, I suspect power issues. The problem lies where the power dies! Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. Remove the filter cartridge to see if it continues. If symptoms continues with the filter on recirculate, you would have different problems, like restriction or obstruction in the pipes. Pump lid not on tight, gasket not lubed, or not positioned properly (superpump) Higher horsepower motors are usually only 230V, above 2 hp, but lower hp motors are sometimes reversible, or have the ability to wire either with 110V or 220V, but they will say this on the motor label if they are (reversible) and have a diagram also. replacement. Yes, if not grounded correctly, the GFCI will trip. ), 2) the pump lid o-ring (is it lubed? Inspect wiring for any loose or corroded connections. goes on first, then the spring, then the slightly larger hole washer. The pump was about 13 years old. Remove the back of the motor and look for anything loose wires, switches, tabs. Do you believe I have a bad breaker? The capacitor is at 9 oclock and the thermal regulator at 12 oclock. It is plugged into a gfi outlet. Going to try 2 hrs low and 6 high. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. If thats not it check the rear of the motor for anything loose (capacitor, centrifugal switch (in the center, on the shaft) or the stationary switch, at 6 oclock, triangular shape. Good thing is our power company is offer rebates for new energy efficient pumps. Capacitors are cheap to replace, order the exact MFD number, printed on it, or you can pick up local at a motor shop. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. The motor may be dead, or possibly not. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. Any thoughts? If lots of air churns when you shut the pump off, and the water quickly blasts out of the pump, thats likely a suction side air leak. K-1766 Taylor Salt Test Hi, it could be the filter, and if so, the pressure on the gauge would be high during operation usually. It worked great for the season. Pull out on the dial, and reset it, until you feel the gears engage. The box is reading no water flow and psi is just above 0. Open the door and inspect for debris with a mirror and flashlight. Upon resetting an electrical short sound came from the pump motor tripping the breaker a second time. Please note: The majority of our literature and brochures are in English only. Hey John Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. But, you probably just need a $15 shaft seal, which is not overly difficult to replace. A leaking shaft seal or drain plug could also drain the pump after some time. Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. 2. loose pipe coming into pump, drawing air around fitting threads Checked circuit breakers inside and out and checked to make sure power is getting to pump. Might be some voltage issues? 2017). 14 x 28 inground, water clear. The pump works and will pump out whatever water is in the line, but wont prime and suck the water from the pool. Inspect for any damage to wires or wire casing. Copyright 2022 In The Swim. Thanks in advance! If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. You can patch the fitting usually with pool putty or silicone, but the best repair is to replace the fitting. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Now what? Yes, pool heaters do have a minimum flow requirement. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. You dont have a saltwater pool do you? Replace cell or entire system Aquatrol RJ with GLX tcell 5, Cheap option for linking a second salt cell, Brand new AquaRite 900 Check Salt and Inspect Cell light, Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Thank you for your time, Jed. If the water is running down between the pump and motor, determine if its dripping out of the plumbing fitting on top or the shaft seal on the bottom. The heat sink is a ridged metal plate beneath the drive, that relies on air flow to help remove heat from the motor. No special tools or lube needed. In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Articles and resources for swimming pool owners and DIYers. You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. Ive never owned a pool before and didnt have any problems all summer until the last 2 weeks. started having the problem Maybe you could just wire the pump directly to the breaker? But after that, you should be able to override any programs with the buttons. 9,000 gallon in ground pool. The motor spins CCW? Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Breakers do wear out, especially if used often as the pump switch. Blower vacuum switch open during post-purge error. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Hello, my motor runs for 20 seconds then stops. *. Your 1 hp Hayward Superpump can pump 75 gallons per minute, which is too much flow for most AG pool filters. We used flocculant and vacuumed through the pump instead of to waste. You have both filter pump and polaris pump on one timer? If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, I was only able to read and yes feel voltage in the pool when the main pump was running only. Shouldnt be having a problem so soon, no but it can happen, but more likely to not be the shaft seal, but the exit pipe, or a leak around the impeller housing, check the bolts around the pump, to be sure they are tight. Reinstall and add new DE powder. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
I have a Hayward pump that will backwash but nothing else. Hi Damon, I would suspect the chattering sound to be a loose stationary switch and/or centrifugal switch on the motor, in the rear of the motor, remove the cover and look for something amiss. If you can remove the handle, you can apply shaving cream and run the pump to see if it gets sucked in put cream around the stem and on both joints in/out of the valve. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. Next year, June 21, 2021, is the date that VS (Variable Speed) pumps will be required, over 1-hp in size. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. Third, is there a valve closed after the filter, or some other obstruction? I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser.
Lynne Benioff Biography,
3m Scotch Tape Dispenser How To Load,
Madison County Dump Jackson, Tn,
Borda Count Calculator,
Komo News Anchor Dies,
Articles H