AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. Step 6: Plant creation succeeds. *, We appreciate your effort and will try to fix the article. Connect the antennae to the data logger; Plug the logger into the inverter - be sure the inverter is on with at least DC power; Open the Wi-Fi settings on your phone and then search for new networks . According to the website my data logger is offline. Go to your web browser - Input 10.10.100.254, 4. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . Click Continuedatalogger to check the monitoring data. or, which is default value. Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. network that uses symbols in the password. If you have not already been registered onSolisCloud, please see Step 18:SolisCloudMonitoring Platform. Data Logging Stick: S2-WL-ST. Support WiFi and LAN communication / Plug and play, quick installation . Connect one end of an ethernet cable to LAN stickand other end directly to a computer. I had to go up to the attic and actually point the antenna towards my router. Monitoring Accessory Configured But Still Won't Link? Wi-Fi communication range: 300m in outdoor open area without obstruction. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. No-Grid - El inversor no reconoce la red. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. Step 4: Click , make sure the phone is connected to router WiFi, and switch back to the page to fill in the WiFi password, then move to the next step. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. SolisCloud App helps you manage PV plant: 1. 1. Step 3: Confirm the plant information.Click Create a plant.Step 4: Click View plant to enter the plant homepage, then add the datalogger. The scripts will process data from the WiFi and LAN Data . Internal DC Short: In the inverter head, or the wirebox? Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. When there is a problem with any of the Solis inverters, plant operation and maintenance (O&M) professionals will appreciate that the GinlongPro APP will connect to the inverter's data logger. A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. This is the same data as can be sent to the ginlogmonitoring.com website for centralised data collection. AGL replaced it free of charge. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. 2019-08-29 16:17:17. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Router has a firewall blocking the data 5. If failed, re-do the configuration process or contact the after-sale engineers. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. It came with a Ginlong data logger wifi stick that I have set up according to the instructions. Is there a trick to setting it up properly that I am missing? 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Thanks, The Boards Team. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. A Wifi-enabled mobile phone is connected to this device parameter setting. Yes did it re-connect on its own or did it need a re-boot. Verify the RSSI (signal strength) is higher than 15%. If it does not reconnect than with your laptop/phone search for new open access point and try to connect to wifi stick, maybe it has lost settings. Open the Local Connection Status, click. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. View the total data of your PV plant. first report in, so please wait until the system begins to show data on. Sorry we couldn't be helpful. app on your phone. 2. https://www.youtube.com/watch?v=0F0aGeTOYw8. You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Solis WIFI and LAN Data Logger Datasheet.pdf, Solis WIFI Logger Installation Manual v2.4 (1).pdf. Did you get a response from Ginlong? i cannot connect my solar wifi data logger to my wifi but it gets connected to my mobile hotspot . Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. I used to have problems like that all the time until I got a wifi mesh system in the house. Step1: Open the datalogger shell and install the SIM caret. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals), 4. We use cookies to try and give you a better experience in Freshdesk. Log in to the page , the username is "admin" and the password is also "admin" 5. Every solar system, regardless of size and complexity benefits from monitoring and this datalogger is the gateway to the informative online platform, SolisCloud. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //.
Svoboda Funeral Home Schuyler Obituaries,
King William County Public Schools Superintendent,
Articles S